|
Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
;
The service manual is a good quality scan of the Panasonic NV-850, which is electrically identical to the Philips VR 6920, but mecanically just nearly.
4.
ERROR MESSAGE
A message may appear while you are adjusting the video camera/recorder. If a message appears, refer to the following table and take appropriate corrective action.
4.1 Digital Adjustments
ERROR MESSAGE ERROR OCCURRED. IRIS TROUBLE PRESS ANY KEY COUNTERMEASURE Check whether or not power is supplied. Check the values of the iris drive circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check the iris block and replace it if necessary. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in theabove circuit. Check the values in the hall amp circuit and its peripheral circuits. Defective soldering, damage to pattern, etc. in the above circuits. The adjustment program (file) cannot be found. Check the adjustment floppy disk and replace it if necessary. The adjustment program (file) does not start. Check the adjustment floppy disk and replace it if necessary. Check the values of the iris drive circuit. Defective soldering, damage to pattern, etc. in the above circuit. Supply power again and re-adjust. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Supply power again and re-adjust. The subject is too bright. Move the camera further away from the light box. The subject is too dark. Check the light box. Move the camera closer to the light box. Supply power again and re-adjust. The subject is too dark. Check the light box. Move the camera closer to the light box. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. The subject is too bright. Move the camera further away from the light box. The subject is too bright or too dark. Check the light box. Move the camera closer to or away from the light box. Supply power again and re-adjust.
ERROR OCCURRED ON da� ADJUSTMENT PRESS ANY KEY D RANGE OVER. ERROR ON da� ADJUSTMENT PRESS ANY KEY. ERROR OCCURRED ON da0 and da1 ADJUSTMENT PRESS ANY KEY FILE NOT FOUND !!!! PRESS ANY KEY FILE OPEN ERROR !!!! PRESS ANY KEY ERROR OCCURRED ON C DUTY ADJUSTMENT PRESS ANY KEY ERROR OCCURRED ON FDET ADJUSTMENT PRESS ANY KEY ERROR OCCURRED. ZOOM DOES NOT WORK PRESS ANY KEY TOO BRIGHT PRESS ANY KEY TOO DARK PRESS ANY KEY D RANGE OVER ERROR ON HALL AMP IRIS CANNOT OPEN ANY MORE PRESS ANY KEY
STAURATION ERROR. TOO BRIGHT PRESS ANY KEY CAN'T ADJUST WHITE BALANCE PLEASE RETRY PRESS ANY KEY
3 - 12
|
|
|
> |
|